Relock Timer

(Radio Wide, GunLock)

HGDefinitionMob.jpg

Selects the minimum amount of time that the corresponding GunLock can be locked again after it has been unlocked. WFForward.png Unlocking a GunLock (1, 2, 3 or All) is radio-user initiated with the corresponding DotRed.png GunLock button-press. DotGreen.png The first record / row, Relock Timer 1, applies to a GunLock 1 button-press, and so on. This feature applies on a radio-wide basis. Time is in seconds.

HGWarning.jpg

 

Control of a GunLock is accomplished through one of the radio's VIP Out pins programmed for GunLock (1-3), where a GunLock 1 button-press activates the VIP Out chosen as "GunLock 1", and so on. WFPrior.png Therefore, you must first select GunLock 1, GunLock 2, or GunLock 3 as a VIP Out; otherwise the corresponding button selection is invalid.

 

For a Dual Radio configuration:

  • When the Radio Selection field is set to "Secondary Radio" the radio's VIP Outputs are disabled; therefore, this feature and the GunLock (1-3) VIP Out pins are only configurable on the "Primary Radio" only.

HGAccessedOnly.jpg

When the radio is model / option capable, and

when the Dual Radio - Radio Selection field is set to "Primary Radio".

HGSelections.jpg

SELECTIONS:

DEFINITIONS:

"Momentary" = 0 (Zero Time):

The corresponding VIP Out deactivates immediately with the release of a DotRed.png GunLock button-press (thereby re-locking the GunLock); the radio-user must keep the button pressed with one hand while using the other hand to remove the gun.

Timed Selections Include:

1 (second)   To    255 (seconds)

In Increments = 1 (second)

DotYellow.png Immediately following a DotRed.png GunLock button-press, the corresponding VIP Out remains active for the selected amount of time.

  • "Relock Timer 1" (that is, the first record / row) applies to a GunLock 1 button-press, and so on.

  • While the VIP Out is still active, pressing the corresponding GunLock button again restarts this Timer.